FANUC Alarm ARC-057 — Cannot ramp t1=… > t2=…
Manufacturer wording — Cannot ramp t1=%d > t2=%d
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC ARC-057 (“Cannot ramp t1=… > t2=…”): The Arc process ramping cannot execute because the delay (t1) to communicate with the welder is larger than the ramping loop time (t2). First check: Increase $aweramp[eq].$time_factor by 1.
Updated 2026-09-17 · LogrobotLM reference
Description
The Arc process ramping cannot execute because the delay (t1) to communicate with the welder is larger than the ramping loop time (t2). This might occur with ramping or HeatWave $awwv_mode 2.
Remedy
Increase $aweramp[eq].$time_factor by 1.