FANUC Alarm DNET-086 — ERR_STOP_C Stop scan cmd failed: Bd …
Manufacturer wording — ERR_STOP_C Stop scan cmd failed: Bd %d
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC DNET-086 (“ERR_STOP_C Stop scan cmd failed: Bd …”): The specified board is unable to acknowledge the stop-scanning command. First check: Check DeviceNet connection to the board, as well as DeviceNet power to the network.
Updated 2026-09-17 · LogrobotLM reference
Description
The specified board is unable to acknowledge the stop-scanning command.
Remedy
Check DeviceNet connection to the board, as well as DeviceNet power to the network. If board is already in ERROR state, this error can be disregarded.