LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm DNET-138 — IDNS unsupported H/W, Bd …

Manufacturer wording — IDNS unsupported H/W, Bd %d
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC DNET-138 (“IDNS unsupported H/W, Bd …”): A DevicNet channel has been configured for safety. First check: Use DN4 DeviceNet hardware or disable safety on this channel.

Updated 2026-09-17 · LogrobotLM reference

Description

A DevicNet channel has been configured for safety. A safety DeviceNet channel requires DN4 hardware. The detected hardware is not supported for a safety channel.

Remedy

Use DN4 DeviceNet hardware or disable safety on this channel.

Related codes