FANUC Alarm FRSY-012 — WARN Invalid file access mode

FANUC FRSY-012 (“WARN Invalid file access mode”): The requested command cannot be performed because the file is not opened with the proper access mode. First check: Open the file with the proper access mode.

Updated 2026-09-17 · LogrobotLM reference

Description

The requested command cannot be performed because the file is not opened with the proper access mode. This error is also caused by trying to update or append to an existing file on the FROM disk or to an existing compressed file on the RAM disk. Update and append are only allowed with uncompressed files on the RAM disk.

Remedy

Open the file with the proper access mode.

Related codes