FANUC Alarm HOST-187 — WARN NETMEM: receive socket open fail
FANUC HOST-187 (“WARN NETMEM: receive socket open fail”): UDP open for datagram receiving was failed. First check: Verify that there is RLSYNC entry in $SERVENT system variable.
Updated 2026-08-29 · LogrobotLM reference
Description
UDP open for datagram receiving was failed.
Remedy · Remède
Verify that there is RLSYNC entry in $SERVENT system variable. Verify that port number for RLSYNC is correct.
Frequently asked · Questions fréquentes
- What does FANUC alarm HOST-187 mean?
- FANUC HOST-187 (“WARN NETMEM: receive socket open fail”): UDP open for datagram receiving was failed.
- How do you troubleshoot FANUC alarm HOST-187?
- Verify that there is RLSYNC entry in $SERVENT system variable. Verify that port number for RLSYNC is correct.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →