LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm ISD-032 — Low pressure warn(disp-…) (ISD…)

Manufacturer wording — Low pressure warn(disp-%s) (ISD%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC ISD-032 (“Low pressure warn(disp-…) (ISD…)”): This error is posted when the system detects too low pressure in the dispensing material. First check: Make sure the dispensing line is ok.

Updated 2026-09-17 · LogrobotLM reference

Description

This error is posted when the system detects too low pressure in the dispensing material. This condition is usually caused by one or more of the following:

Remedy

Make sure the dispensing line is ok. Make sure the dispensing flow rate is not too low. Make sure the low pressure limit value is appropriate. Make sure the low pressure time out value is appropriate.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →