FANUC Alarm LECO-053Cap B over voltage (Cap A volts, Cap B volts)

Description

The voltage on one of the two input capacitor banks (bank B) has exceeded the high voltage limit. This is normally caused by high input voltage but it could be caused by a faulty switch board, main capacitor, contactor, or V-to-F feedback signal.

Remedy · Remède

Check the input power (voltage and frequency). Verify the primary reconnect is properly configured for the input voltage.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.