FANUC Alarm MHND-010 — WARN Cycle power to change registers

FANUC MHND-010 (“WARN Cycle power to change registers”): An old smaller POSREG.VR file was loaded onto the controller. First check: M.H. Shell logic has automatically set the number of position registers to the necessary size again.

Updated 2026-09-17 · LogrobotLM reference

Description

An old smaller POSREG.VR file was loaded onto the controller. The number of position registers was changed to fewer than what the current version of M.H. Shell needs.

Remedy

M.H. Shell logic has automatically set the number of position registers to the necessary size again. But a cold start is needed to increase the position register table size. Do a cold start.