FANUC Alarm TPIF-140 — Connection limit exceeded

FANUC TPIF-140 (“Connection limit exceeded”): An attempt to log into the teach pendant menuing system from an external web browser has failed because the connection limit has been reached. First check: The system variable $UI_CONFIG.$NUM_CONNECT controls the number of external connections allowed.

Updated 2026-09-17 · LogrobotLM reference

Description

An attempt to log into the teach pendant menuing system from an external web browser has failed because the connection limit has been reached.

Remedy

The system variable $UI_CONFIG.$NUM_CONNECT controls the number of external connections allowed. The maximum number of connections is five INCLUDING the teach pendant. Reconnect the external connections in your system so that no more than five exist.