FANUC Alarm VARS-032 — WARN Variable size too big

FANUC VARS-032 (“WARN Variable size too big”): The variable you are loading is larger than 65,535 bytes or has an array element larger than 32,767 bytes First check: Make the array size smaller or use a path data type for large arrayed variables Maximum path length is 2,007 Maximum node size is 32,767

Updated 2026-09-17 · LogrobotLM reference

Description

The variable you are loading is larger than 65,535 bytes or has an array element larger than 32,767 bytes

Remedy

Make the array size smaller or use a path data type for large arrayed variables Maximum path length is 2,007 Maximum node size is 32,767

Related codes