ABB Error 0102 — CPU / EPROM fault
Error / Erreur🇫🇷 CPU / EPROM
GÉNÉRATION S2 / S3 — CODES HISTORIQUES (5xx & SOUS-CODES)
ABB 0102 (“CPU / EPROM fault”): CPU / EPROM fault — ABB robot hardware event on the CPU / EPROM (S2/S3). Likely part: CPU / EPROM (CPU / EPROM).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
CPU / EPROM fault — ABB robot hardware event on the CPU / EPROM (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
Erreur de checksum PROM sur la carte du calculateur d'E/S.
What to check · Que vérifier
- Inspect the CPU / EPROM, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- A Remplacez les EPROM de la carte de commande.
- B Remplacez la carte du calculateur principal.
- À savoir : Deviendra l'erreur PROM 31601/31602 de S4 et flash endommagée sur IRC5.
Part to check / replace · Pièce à contrôler / remplacer
ABB 0102 points to the hardware below — start here before ordering. · 0102 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 0102 mean?
- ABB 0102 (“CPU / EPROM fault”): CPU / EPROM fault — ABB robot hardware event on the CPU / EPROM (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 0102?
- Inspect the CPU / EPROM, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 0102?
- 0102 points to CPU / EPROM (CPU / EPROM). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →