ABB Error 0114 — Enabling chain fault
Error / Erreur🇫🇷 Chaîne de validation
GÉNÉRATION S2 / S3 — CODES HISTORIQUES (5xx & SOUS-CODES)
ABB 0114 (“Enabling chain fault”): Enabling chain fault — ABB robot hardware event on the enabling chain (S2/S3). Likely part: DSQC 211 (enabling chain).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Enabling chain fault — ABB robot hardware event on the enabling chain (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
Erreur matérielle lors du test automatique de la chaîne de validation (circuit d'arrêt de sécurité).
What to check · Que vérifier
- Inspect the enabling chain, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- A Remplacez la carte calculateur.
- B Remplacez le bloc d'alim DSQC 211.
- C Remplacez le fond de panier.
- À savoir : Deviendra les défauts d'alimentation ou de carte de contacteurs d'entraînement d'armoire.
Part to check / replace · Pièce à contrôler / remplacer
ABB 0114 points to the hardware below — start here before ordering. · 0114 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 0114 mean?
- ABB 0114 (“Enabling chain fault”): Enabling chain fault — ABB robot hardware event on the enabling chain (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 0114?
- Inspect the enabling chain, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 0114?
- 0114 points to DSQC 211 (enabling chain). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →