ABB Error 33105 — Power supply resolver fault
Error / Erreur🇫🇷 Alimentation Résolveurs
CALCULATEURS, MÉMOIRE & COMMUNICATION (31xxx–33xxx)
ABB 33105 (“Power supply resolver fault”): Power supply resolver fault — ABB robot hardware event on the power supply resolver (S4/S4C). Likely part: Alimentation Résolveurs (power supply resolver).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Power supply resolver fault — ABB robot hardware event on the power supply resolver (S4/S4C). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
Échec d'alimentation électrique d'excitation des résolveurs du manipulateur.
What to check · Que vérifier
- Inspect the power supply resolver, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Vérifier l'alimentation des résolveurs (générée par la carte de commande d'axes d'armoire ou SMB).
- À savoir : Deviendra les pannes de tension d'alimentation de résolveurs sur IRC5.
Part to check / replace · Pièce à contrôler / remplacer
ABB 33105 points to the hardware below — start here before ordering. · 33105 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 33105 mean?
- ABB 33105 (“Power supply resolver fault”): Power supply resolver fault — ABB robot hardware event on the power supply resolver (S4/S4C). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 33105?
- Inspect the power supply resolver, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 33105?
- 33105 points to Alimentation Résolveurs (power supply resolver). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →