ABB Error 39406 — Field loop overcurrent
ErrorABB 39406 (“Field loop overcurrent”): Field loop overcurrent: the field current control loop has produced a current that is too high for the indicated joint, connected to the indicated drive module. Likely part: Boucle de champ / Variateur (Boucle de champ / Variateur).
Updated 2026-10-22 · LogrobotLM reference
What it means
Field loop overcurrent: the field current control loop has produced a current that is too high for the indicated joint, connected to the indicated drive module.
What to check
- Check the motor cable and the winding insulation of the affected axis.
- Check the drive unit controlling the axis.
- Only replace the drive unit after measuring on the motor side: a loop overcurrent more often comes from the load than from the electronics.
- Note: 394xx family: the message names the joint (arg), to be noted before acknowledgement.
Part to check / replace
ABB 39406 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →