ABB Error 39414 — Controller hardware fault
Error / Erreur🇫🇷 Unité condensateurs / DC-Link
VARIATEURS & COMMUNICATION DRIVE (39xxx, 3254x)
ABB 39414 (“Controller hardware fault”): Controller hardware fault — ABB robot hardware event on the controller hardware (IRC5). Likely part: Unité condensateurs / DC-Link (Unité condensateurs / DC-Link).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Controller hardware fault — ABB robot hardware event on the controller hardware (IRC5). Seen across controller generations. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Code type de l’unité de condensateurs inconnu du système.
What to check · Que vérifier
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Contrôler le type de capacitor unit installé et sa compatibilité avec le logiciel; remplacer l’unité si le type est incorrect.
- À savoir : Défaut matériel/compatibilité du module condensateurs.
Part to check / replace · Pièce à contrôler / remplacer
ABB 39414 points to the hardware below — start here before ordering. · 39414 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 39414 mean?
- ABB 39414 (“Controller hardware fault”): Controller hardware fault — ABB robot hardware event on the controller hardware (IRC5). Seen across controller generations. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 39414?
- Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault. Contrôler le type de capacitor unit installé et sa compatibilité avec le logiciel; remplacer l’unité si le type est incorrect.
- Which part is involved in ABB 39414?
- 39414 points to Unité condensateurs / DC-Link (Unité condensateurs / DC-Link). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →