ABB Error 39428 — Rectifier startup error
ErrorABB 39428 (“Rectifier startup error”): Rectifier startup error: the rectifier on the drive module communication link has detected an error at start-up. Likely part: Redresseur / Séquence de démarrage (Redresseur / Séquence de démarrage).
Updated 2026-10-22 · LogrobotLM reference
What it means
Rectifier startup error: the rectifier on the drive module communication link has detected an error at start-up. Probable cause: an internal error in the rectifier unit. The system goes to SYS HALT.
What to check
- Check that the signal cable is correctly connected between the rectifier and the drive unit.
- Perform a shutdown and then restart the cabinet — a simple acknowledgement does not replay the start-up sequence.
- If the fault recurs, isolate the faulty rectifier unit and replace it.
- Note: Error that only appears at power-up: no point looking for it during operation. Complements 39426 / 39427.
Part to check / replace
ABB 39428 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →