ABB Error 511 — Memory DSMB 125 fault
Error / Erreur🇫🇷 Mémoire DSMB 125
GÉNÉRATION S2 / S3 — CODES HISTORIQUES (5xx & SOUS-CODES)
ABB 511 (“Memory DSMB 125 fault”): Memory DSMB 125 fault — ABB robot hardware event on the memory DSMB 125 (S2/S3). Likely part: Mémoire DSMB 125 (memory DSMB 125).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Memory DSMB 125 fault — ABB robot hardware event on the memory DSMB 125 (S2/S3). Specific to this controller generation. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
Défaut de taille de mémoire vive. La carte mémoire DSMB 125 est manquante ou en panne physique.
What to check · Que vérifier
- Inspect the memory DSMB 125, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Corrigez l'origine de l'erreur.
- Rechargez les paramètres fonctionnels avec la PROM ou le DISQUE.
- À savoir : Spécifique à la carte d'extension mémoire DSMB 125 d'époque S2/S3.
Part to check / replace · Pièce à contrôler / remplacer
ABB 511 points to the hardware below — start here before ordering. · 511 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 511 mean?
- ABB 511 (“Memory DSMB 125 fault”): Memory DSMB 125 fault — ABB robot hardware event on the memory DSMB 125 (S2/S3). Specific to this controller generation. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 511?
- Inspect the memory DSMB 125, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 511?
- 511 points to Mémoire DSMB 125 (memory DSMB 125). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →