ABB Error 585Teach pendant fault

Error / Erreur

🇫🇷 Console de Prog.

GÉNÉRATION S2 / S3 — CODES HISTORIQUES (5xx & SOUS-CODES)

ABB 585 (“Teach pendant fault”): Teach pendant fault — ABB robot hardware event on the teach pendant (S2/S3). Likely part: Console de Prog. (teach pendant).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Teach pendant fault — ABB robot hardware event on the teach pendant (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Erreur d'initialisation matérielle de la console de programmation (teach pendant) au démarrage.

What to check · Que vérifier

  • Inspect the teach pendant, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Consulter le chapitre 6.
  • Vérifier le câblage de la console de programmation.
  • À savoir : Similaire aux erreurs de démarrage ou de communication du FlexPendant de l'IRC5.

Part to check / replace · Pièce à contrôler / remplacer

ABB 585 points to the hardware below — start here before ordering. · 585 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 585 mean?
ABB 585 (“Teach pendant fault”): Teach pendant fault — ABB robot hardware event on the teach pendant (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 585?
Inspect the teach pendant, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 585?
585 points to Console de Prog. (teach pendant). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →