LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 594Shunt resistor fault

Error / Erreur

🇫🇷 Résistance de Shunt

GÉNÉRATION S2 / S3 — CODES HISTORIQUES (5xx & SOUS-CODES)

ABB 594 (“Shunt resistor fault”): Shunt resistor fault — ABB robot hardware event on the shunt resistor (S2/S3). Likely part: Résistance de Shunt (shunt resistor).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Shunt resistor fault — ABB robot hardware event on the shunt resistor (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Température excessive de la résistance shunt d'absorption de l'énergie de freinage.

What to check · Que vérifier

  • Inspect the shunt resistor, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Vérifier la tension d'entrée du redresseur.
  • Réduire les accélérations du robot.
  • À savoir : Deviendra l'erreur de surcharge de bleeder resistor (39444) ou de circuit ouvert de bleeder (34257) sur IRC5.

Part to check / replace · Pièce à contrôler / remplacer

ABB 594 points to the hardware below — start here before ordering. · 594 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 594 mean?
ABB 594 (“Shunt resistor fault”): Shunt resistor fault — ABB robot hardware event on the shunt resistor (S2/S3). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 594?
Inspect the shunt resistor, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 594?
594 points to Résistance de Shunt (shunt resistor). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →