ABB Error 594 — Shunt resistor fault

Error

ABB 594 (“Shunt resistor fault”): Excessive temperature of the shunt resistor that absorbs the braking energy. Likely part: Résistance de Shunt (shunt resistor).

Updated 2026-10-22 · LogrobotLM reference

What it means

Excessive temperature of the shunt resistor that absorbs the braking energy.

What to check

  • Check the rectifier input voltage.
  • Reduce the robot accelerations.
  • Note: Will become the bleeder resistor overload error (39444) or the bleeder open circuit error (34257) on IRC5.