FANUC Alarm ARC-090 — WARN Weld disable by reason

Manufacturer wording — WARN Weld disable by reason[%d]
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC ARC-090 (“WARN Weld disable by reason”): In this situation, the welding is disalbled by the following reason 1: In Single step mode 2: In Machine lock mode 3: In Dry run mode 4: No I/O board exist 5: No I/O assignment for welding 6: In Flush First check: Please remove the specified reason to perform the welding.

Updated 2026-09-17 · LogrobotLM reference

Description

In this situation, the welding is disalbled by the following reason 1: In Single step mode 2: In Machine lock mode 3: In Dry run mode 4: No I/O board exist 5: No I/O assignment for welding 6: In Flush AMR status 7: In Application disabled mode 8: In Arc disabled status 9: In Skip welding status 10: In disable status mode by AWDBG

Remedy

Please remove the specified reason to perform the welding.