FANUC Alarm ARC-091 — Arc End cannot ramp to position (%s^4,%d^5)
Description
An Arc End weld schedule specified a time of 99.0 seconds. This time value is sometimes used with Arc Starts to indicate ramping during an entire motion. This type of ramping is not available for an Arc End. A time of 99.0 seconds for an Arc End craterfill time is very long and is not recommended. If a long time is needed then 98.0 seconds will work without this error.
Remedy · Remède
Use a different weld schedule for the Arc End or change the time value to a smaller value.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.