FANUC Alarm ARC-179Power supply com alarm(E:%d)

Description

This alarm occurs when communication between the welding equipment control board and the robot controller stops.

Remedy · Remède

1. If this alarm occurred with ARC-143, please perform the remedy for ARC-143. 2. If this alarm is still occurred after restarting the system, check the wiring between the controller and welding power supply. If problem is not found, check the power supply control board.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.