FANUC Alarm DNET-102WARN Invalid board MAC Id

Description

The board’s MAC Id is not between 0 and 63.

Remedy · Remède

Check the Board Detail screen to see if the board’s MAC Id is between 0 - 63, inclusive. If it is not, change the MAC Id to a valid value and press RESET on the teach pendant. If the MAC Id appears valid, cold start the controller. If the problem persists, document the events that led to the error and call your FANUC Robotics technical representative.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.