FANUC Alarm DNET-103 — WARN Invalid board baud rate
Description
The board’s baud rate is not one of: 125 KB, 250 KB, or 500 KB.
Remedy · Remède
Check the Board Detail screen to see if the board's baud rate is one of the above values. If it is not, change the baud rate to a valid value and press RESET on the teach pendant. If the baud rate appears valid, cold start the controller. If the problem persists, document the events that led to the error and call your FANUC Robotics technical representative.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.