FANUC Alarm DNET-114 — WARN Bus fault error detected
FANUC DNET-114 (“WARN Bus fault error detected”): The board has detected a fault on the DeviceNet network, and cannot communicate with devices. First check: Check that the baud rate of the board matches the baud rate of all devices on the network.
Updated 2026-09-17 · LogrobotLM reference
Description
The board has detected a fault on the DeviceNet network, and cannot communicate with devices.
Remedy
Check that the baud rate of the board matches the baud rate of all devices on the network. Also, check that power is being supplied to the network. If the problem persists, cycle power to the controller, and then to the network if the problem continues.
Related codes