FANUC Alarm FRCE-275 — Phase matching timeout (F:%d^1)
FANUC FRCE-275 (“Phase matching timeout (F:%d^1)”): Insertion time exceeded the upper limit during the phase match insertion. First check: 1. Increase the value of 'Phase Match Rot Vel' in Basic Data.
Updated 2026-08-29 · LogrobotLM reference
Description
Insertion time exceeded the upper limit during the phase match insertion.
Remedy · Remède
1. Increase the value of 'Phase Match Rot Vel' in Basic Data. 2. Increase the value of 'Phase Match Torque' in Performance Data. 3. Phase match insertion works well in a range of about 20 degrees. Make sure that the phases of the workpiece and the object match in this rotation. 4. Make sure that the insertion clearance is large enough.
Frequently asked · Questions fréquentes
- What does FANUC alarm FRCE-275 mean?
- FANUC FRCE-275 (“Phase matching timeout (F:%d^1)”): Insertion time exceeded the upper limit during the phase match insertion.
- How do you troubleshoot FANUC alarm FRCE-275?
- 1. Increase the value of 'Phase Match Rot Vel' in Basic Data. 2. Increase the value of 'Phase Match Torque' in Performance Data. 3. Phase match insertion works well in a range of about 20 degrees. Make sure that the phases of the workpiece and the object match in this rotation. 4. Make sure that the insertion…
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →