FANUC Alarm INTP-445 — Indirection in Fast mode
Manufacturer wording — (%s^4, %d^5) Indirection in Fast mode
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC INTP-445 (“Indirection in Fast mode”): There is an indirection of index, (ex. First check: Remove the indirection, or execute this program in Normal mode Background Logic
Updated 2026-09-17 · LogrobotLM reference
Description
There is an indirection of index, (ex. DI[R[1]]), in Fast mode Background Logic. Fast mode Background Logic cannot use indirection.
Remedy
Remove the indirection, or execute this program in Normal mode Background Logic
Related codes