LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm ISD-023 — WARN Meter switching fault (ISD…)

Manufacturer wording — WARN Meter switching fault (ISD%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC ISD-023 (“WARN Meter switching fault (ISD…)”): This warning is posted when the inactive meter could not finish reloading before the active meter reaches the Near-Empty position. First check: -  Make sure material supply pressure is high enough.

Updated 2026-09-17 · LogrobotLM reference

Description

This warning is posted when the inactive meter could not finish reloading before the active meter reaches the Near-Empty position. This is where the sub-meter should start dispensing for meter switching. This condition is usually caused by one or more of the following:

Remedy

-  Make sure material supply pressure is high enough. -  Make sure the Near-Empty location is set properly. -  Nake sure the PLC sends the RELOAD_OK on time.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →