FANUC Alarm ISD-025 — WARN Reload sequence fault (ISD%d)
Description
This warning is posted when the previous reload did not finish when the meter was switched. This condition is usually d by one or more of the following:
Remedy · Remède
- Make sure the material supply pressure is high enough. - Make sure Near-Empty location is set properly . - Make sure PLC sends RELOAD_OK on time. - Make sure the RELOAD_OK is cleared on time.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.