LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm ISD-080 — … high flow warn (ISD…)

Manufacturer wording — %s high flow warn (ISD%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC ISD-080 (“… high flow warn (ISD…)”): The software has detected a high flow level for the ISO/POLY material. First check: The ISO/POLY flow rate has exceeded the "ISO/POLY Max Warn Flow" level for a period of time greater than the "Flow Lo/Hi Time Out" duration.

Updated 2026-09-17 · LogrobotLM reference

Description

The software has detected a high flow level for the ISO/POLY material.

Remedy

The ISO/POLY flow rate has exceeded the "ISO/POLY Max Warn Flow" level for a period of time greater than the "Flow Lo/Hi Time Out" duration. Verify that the dispense equipment (pressure regulators, flow meters and spray modules, etc.) is functioning correctly. Verify that the settings on the Dispenser Setup screen are reasonable.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →