LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm ISD-083 — … low flow (ISD…)

Manufacturer wording — %s low flow (ISD%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC ISD-083 (“… low flow (ISD…)”): The software has detected an excessively low flow level for the ISO/POLY material. First check: The ISO/POLY flow rate was less than the "ISO/POLY Min Fault Flow" level for a period of time greater than the "Flow Lo/Hi Time Out" duration.

Updated 2026-09-17 · LogrobotLM reference

Description

The software has detected an excessively low flow level for the ISO/POLY material. This case is more severe than ISD-082, and may result in serious material application defects.

Remedy

The ISO/POLY flow rate was less than the "ISO/POLY Min Fault Flow" level for a period of time greater than the "Flow Lo/Hi Time Out" duration. Verify that the dispense equipment (pressure regulators, flow meters and spray modules, etc.) is functioning correctly. Verify that the settings on the Dispenser Setup screen are reasonable.

Related codes