LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PAIN-176 — PAUS TP OFF in T1,T2/Door open

FANUC PAIN-176 (“PAUS TP OFF in T1,T2/Door open”): Teach Pendant is disabled when mode switch is T1 or T2 Or Controller door is opened Or mis-wiring of hardware connection First check: Change the TP Enable/Disable switch to ON And close controller door And press RESET If the reset is not effective, correct hardware connection

Updated 2026-09-17 · LogrobotLM reference

Description

Teach Pendant is disabled when mode switch is T1 or T2 Or Controller door is opened Or mis-wiring of hardware connection

Remedy

Change the TP Enable/Disable switch to ON And close controller door And press RESET If the reset is not effective, correct hardware connection

Related codes