FANUC Alarm PAIN-541 — WARN %sLower output did not lower flow
Description
As the AccuAir calibration steps down through the 10 points in the calibration table, it expects a lower flow for each decrease in the command flow value. In this case the flow did not decrease. This can be d by insufficient exhaust, no quick exhaust on the pilot air line, too large of a hysteresis in control equipment, or the system response is too slow for the current setting of the Calibration step delay parameter.
Remedy · Remède
Retry the calibration. Check that the pilot air line to the booster has sufficient exhaust capability. Increase the Calibration step delay parameter (by about 100%). Reducing the Leveling tries parameter may help.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.