FANUC Alarm PNT1-166 — Linear Potentiometer Unstable

FANUC PNT1-166 (“Linear Potentiometer Unstable”): During Auto Calibration, the feedback from the linear potentiometer revealed large fluctuations in the canister position over a short period of time. First check: Change the applicator and repair the malfunctioning linear potentiometer.

Updated 2026-09-17 · LogrobotLM reference

Description

During Auto Calibration, the feedback from the linear potentiometer revealed large fluctuations in the canister position over a short period of time. If the linear potentiometer has been improperly installed or the magnet has been misaligned, it might cause this alarm.

Remedy

Change the applicator and repair the malfunctioning linear potentiometer. Retry calibration with a different applicator.