FANUC Alarm PNT1-568 — %sMax. output has flow < setpoint
FANUC PNT1-568 (“%sMax. output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). First check: Check the following:
Updated 2026-08-29 · LogrobotLM reference
Description
With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The gun might be clogging. A fluid or pilot air line might be pinched. The fluid pressure might have become too low. The I/P transducer might be broken. Note: Accuflow automatically changes to Open Loop when this failure occurs.
Remedy · Remède
Check the following:
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT1-568 mean?
- FANUC PNT1-568 (“%sMax. output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The gun might be clogging. A fluid or pilot air line might be pinched. The fluid pressure might have become too low. The I/P transducer might be broken.…
- How do you troubleshoot FANUC alarm PNT1-568?
- Check the following:
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →