FANUC Alarm PNT1-568 — Max. output has flow < setpoint
Manufacturer wording — %sMax. output has flow < setpoint
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT1-568 (“Max. output has flow < setpoint”): With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). First check: Check the following:
Updated 2026-09-17 · LogrobotLM reference
Description
With a maximum control output, the flow rate was measured to be lower than the setpoint (requested flow). The gun might be clogging. A fluid or pilot air line might be pinched. The fluid pressure might have become too low. The I/P transducer might be broken. Note: Accuflow automatically changes to Open Loop when this failure occurs.
Remedy
Check the following: