FANUC Alarm PNT1-635 — %sCal. table adapted out, down
FANUC PNT1-635 (“%sCal. table adapted out, down”): The relationship of the output command to the flow rate obtained has changed significantly since the last calibration. First check: Check and perform the following:
Updated 2026-08-29 · LogrobotLM reference
Description
The relationship of the output command to the flow rate obtained has changed significantly since the last calibration. There is now a smaller output required to get the same flow rate. This can be caused by: air leaks, a loose air cap, or a significant increase of air supply pressure. Note that the system continues to close the loop and generally maintain requested flow rates even after this alarm if there are no other alarms occurring. This alarm can provide an early warning of the possible failures. This alarm is controlled by the Adaptive tolerance parameter.
Remedy · Remède
Check and perform the following:
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT1-635 mean?
- FANUC PNT1-635 (“%sCal. table adapted out, down”): The relationship of the output command to the flow rate obtained has changed significantly since the last calibration. There is now a smaller output required to get the same flow rate. This can be caused by: air leaks, a loose air cap, or a significant increase of…
- How do you troubleshoot FANUC alarm PNT1-635?
- Check and perform the following:
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →