LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PNT2-135 — TP OFF in T1,T2/Door open

FANUC PNT2-135 (“TP OFF in T1,T2/Door open”): The teach pendant is disabled when the mode switch is in T1 or T2 mode. First check: Change the teach pendant Enable/Disable switch to ON, and close the controller door and press RESET.

Updated 2026-09-17 · LogrobotLM reference

Description

The teach pendant is disabled when the mode switch is in T1 or T2 mode. Or, the controller door is opened or mis-wiring of hardware connection has occurred.

Remedy

Change the teach pendant Enable/Disable switch to ON, and close the controller door and press RESET. If the reset is not effective, correct hardware connection.

Related codes