LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm PNT2-599%sRequested flow above cal. table

Description

Accustat could not reach the upper flow limit in the number of times set at the calibration screen. The upper limit flow rate can not be achieved. Fluid restricter is too small. The flow rate or can position feedback is unstable.

Remedy · Remède

Verify all equipment is working properly. Check Color Data upper limit. Check applicator parameters to make sure that App Parameter Max limit is not below the AccuStat Color Data upper limit. Increase Auto cal hi/low tolerance or Trys for hi/low from the AccuStat setup screen. Check feedback.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.