FANUC Alarm PNT2-659 — %sRequested flow above cal. table
Description
The requested air flow setpoint is above the calibrated range for Fan Air. The maximum value is shown as point number 10 in the calibration table.
Remedy · Remède
Adjust the air flow setpoint to be within the calibrated range of this parameter. Perform the necessary steps to increase the maximum flow obtained during calibration. This might involve increasing the diameter of the air lines supplying Fan air to the applicator or changing the type of air booster used.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.