FANUC Alarm PNT2-756 — %sPump 2 IN high pressure fault
Description
Pump #2 inlet pressure has been above the high fault limit for a user configurable period of time. This condition is usually caused by one or more of the following:
Remedy · Remède
Make sure the high pressure fault limit is appropriate. Make sure the high pressure sensitivity is appropriate. Make sure the supply pressure is appropriate. Check the hardener inlet transducer as follows: Through the Analog I/O menu verify the transducer is spanning from near 200 cnts (0 psi) to 600+ cnts (50-80 psi) during a color change cycle. Check the hardener inlet regulator as follows: Through the Analog I/O menu verify the command 200-1000 cnts (0-100 psi) spanning by verifying the output psi at the transducer test port.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.