FANUC Alarm PNT2-811 — Pump 2 totals differ > tolerance

Manufacturer wording — %sPump 2 totals differ > tolerance
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-811 (“Pump 2 totals differ > tolerance”): The actual total flow out of pump #2 as measured by the fluid flow meter has a value that is different than the commanded total flow. First check: Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev).

Updated 2026-09-17 · LogrobotLM reference

Description

The actual total flow out of pump #2 as measured by the fluid flow meter has a value that is different than the commanded total flow. This difference is larger than the total flow tolerance.

Remedy

Do a fluid flow test on pump #2 with a beaker and verify that the beaker amount matches the pump #2 size (cc/rev). Verify that the correct KFT factor has been entered for the flow meter per the manufacturers specification. Check the operation of the inlet regulator to verify that no (blow by) is occurring across the pump. Verify that pump #2 does not have excessive wear.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →