FANUC Alarm PNT2-832%s

FANUC PNT2-832 (“%s”): An attempt was made to extend or retract the valve at SpeedDock side A or B, but failed. First check: Check the retract or extend sensor at SpeedDock side A or B.

Updated 2026-08-29 · LogrobotLM reference

Description

An attempt was made to extend or retract the valve at SpeedDock side A or B, but failed.

Remedy · Remède

Check the retract or extend sensor at SpeedDock side A or B. If it was an extended fault, ensure that the pusher extended fully at Speed Dock side A or B. If it was a retracted fault, ensure that the pusher retracted fully at SpeedDock side A or B and that the valve is not stuck in the extended state. Ensure that sufficient air pressure is available for this operation and that the air lines are connected.

Frequently asked · Questions fréquentes

What does FANUC alarm PNT2-832 mean?
FANUC PNT2-832 (“%s”): An attempt was made to extend or retract the valve at SpeedDock side A or B, but failed.
How do you troubleshoot FANUC alarm PNT2-832?
Check the retract or extend sensor at SpeedDock side A or B. If it was an extended fault, ensure that the pusher extended fully at Speed Dock side A or B. If it was a retracted fault, ensure that the pusher retracted fully at SpeedDock side A or B and that the valve is not stuck in the extended state. Ensure that…

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →