FANUC Alarm PRIO-186 — WARN CNET Invalid Header size
FANUC PRIO-186 (“WARN CNET Invalid Header size”): The input header size in case of scanner mode or the output header size in case of adapter is invalid. First check: Enter a valid header size.
Updated 2026-09-17 · LogrobotLM reference
Description
The input header size in case of scanner mode or the output header size in case of adapter is invalid.
Remedy
Enter a valid header size. The valid header is less that or equal to the total connection size. The total connection size is a sum of the I/O size and the header size.