LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm SEAL-024WARN Error in motion triggering

Description

The high performance I/O triggering system (Motion Trigger) has returned a bad status. When this occurs, the redundant triggering system will take over, but the quality of the SSs and SEs will be poor. This condition is usually d by one or more of the following: 1. A Gun On output is assigned to a output point which is nonzero and does not exist. 2. A Start Meter output is assigned to a output point which is nonzero and does not exist. 3. A Atomizing Air output is assigned to a output point which is nonzero and does not exist. 4. There is a problem with the software setup of the I/O system. 5. There is a problem with the hardware setup of the I/O system .

Remedy · Remède

Go to the Equipment Output menu and verify that all the Gun on, Start Meter, and Atomizing Air outputs are correctly defined or their indexes are set to zero. If the VALUE of a output port is '****', then the index number must be set to zero and the robot must be cold started. You must cold start the robot after changing anything on this menu.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.