FANUC Alarm SEAL-095 — WARN Nozzle under pressure (E…)
Manufacturer wording — WARN Nozzle under pressure (E%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC SEAL-095 (“WARN Nozzle under pressure (E…)”): Nozzle pressure has dropped below setpoint value for more than time limit. First check: Use on-board diagnostics on the dispenser controller to verify that the nozzle pressure sensor is in order, replace sensor as required.
Updated 2026-09-17 · LogrobotLM reference
Description
Nozzle pressure has dropped below setpoint value for more than time limit.
Remedy
Use on-board diagnostics on the dispenser controller to verify that the nozzle pressure sensor is in order, replace sensor as required.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →