FANUC Alarm SEAL-177WARN EOAT timed out: Flip

Description

The Four Position End of Arm tool was moved, but the FLIP sensor reports that the tool is not in the correct FLIP/UNFLIP position (could be ON or OFF) after the timeout period set on the tool setup menu expired.

Remedy · Remède

Check air supply to the four position tool. Check proximity sensors on the four position tool. If the tool is slow, increase the timeout delay on the tool setup screen to allow enough time for the tool to complete motion.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.