FANUC Alarm SPOT-104 — PAUSE Backup close fault %s-gun 1
FANUC SPOT-104 (“PAUSE Backup close fault %s-gun 1”): The BU Close Detect input was not received within the specified timeout period. First check: Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).
Updated 2026-08-29 · LogrobotLM reference
Description
The BU Close Detect input was not received within the specified timeout period.
Remedy · Remède
Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).
Frequently asked · Questions fréquentes
- What does FANUC alarm SPOT-104 mean?
- FANUC SPOT-104 (“PAUSE Backup close fault %s-gun 1”): The BU Close Detect input was not received within the specified timeout period.
- How do you troubleshoot FANUC alarm SPOT-104?
- Verify the input is assigned correctly; verify the input is being made when the backup gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$bu_cl_to).
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →