SPOT-000WARN Unknown error (SWG0)SPOT-001PAUSE Backup not closed …SPOT-002PAUSE Iso contactor fault …SPOT-003PAUSE Water saver OK fault …SPOT-004PAUSE Water flow OK fault …SPOT-005PAUSE X-former OK fault …SPOT-006PAUSE Weld enable mismatch …SPOT-007PAUSE Weld in process timeout …SPOT-008PAUSE Weld complete timeout …SPOT-009WARN Got weld complete early …SPOT-010PAUSE Major alarm detected …SPOT-011WARN Minor alarm detected …SPOT-012PAUSE Bad schedule (S=…)SPOT-013PAUSE Undefined pressure (P=*)SPOT-014PAUSE BACKUP CLOSE DETECT timed out …SPOT-015PAUSE GUN CLOSE DETECT timed out …SPOT-016PAUSE BACKUP OPEN DETECT timed out …SPOT-017PAUSE GUN OPEN DETECT timed out …SPOT-018PAUSE Serial comm error …SPOT-019PAUSE Serial polling timeoutSPOT-020PAUSE Not in safe starting positionSPOT-021PAUSE GUN CLOSE DETECT input is on …SPOT-022PAUSE GUN OPEN DETECT input is on …SPOT-023PAUSE BU CLOSE DETECT is on …SPOT-024PAUSE BU OPEN DETECT is on …SPOT-025PAUSE Bad pressure (P=…)SPOT-026PAUSE Reset welder timeout …SPOT-027PAUSE Serial sequence not startedSPOT-028PAUSE Serial initialization failedSPOT-029PAUSE Serial option not loadedSPOT-030PAUSE Gun contactor fault …SPOT-031PAUSE Gun open fault …SPOT-032PAUSE Gun close fault …SPOT-033PAUSE Backup open fault …SPOT-034PAUSE Backup close fault …SPOT-035PAUSE Invalid equipment (… defined)SPOT-036PAUSE Invalid weld controller (… defined)SPOT-037WARN No gun contactors definedSPOT-038WARN Stud feeders lowSPOT-039PAUSE System air pressure below 85psiSPOT-040WARN Stud Welder Not ReadySPOT-041WARN Tool not attached …SPOT-042WARN Stud Welder Time Out FaultSPOT-043PAUSE Stud Welder Weld FaultSPOT-044WARN Stud Welder Arc Voltage FaultSPOT-045WARN No Current detected: …SPOT-046WARN Weld auto retried … time(s)SPOT-047WARN Collision Detection AlarmSPOT-048PAUSE No Coll. Guard Reg. DefinedSPOT-049PAUSE Coll. Guard Reg. Data ErrorSPOT-050PAUSE Bad Pressure (EP=…)SPOT-051PAUSE Undefined Pressure (EP=*)SPOT-052PAUSE Suspect WeldSPOT-053WARN Feeder Low - Gun1SPOT-054WARN Feeder Low - Gun2SPOT-055PAUSE Stud Controller Fault1SPOT-056PAUSE Weld Head Not Retracted-Gun1SPOT-057PAUSE Weld Head Not Retracted-Gun2SPOT-058PAUSE Studwelder - Air Pressure LowSPOT-059PAUSE Stud Controller Fault2SPOT-060Robot Not At Home PositionSPOT-061Request FailedSPOT-062Please retry function againSPOT-063STOP …SPOT-064WARN …SPOT-065WARN …SPOT-066WARN Iwc NOT readySPOT-067PAUSE No Shunt Trip output for WC:…SPOT-068Weld done input not mapped …SPOT-069Studwelder Maintenance onSPOT-070Internal Error (system)SPOT-071PAUSE Backup not closed-gun 1SPOT-072PAUSE Iso contactor fault-gun 1SPOT-073PAUSE Water saver fault-gun 1SPOT-074PAUSE Water flow fault-gun 1SPOT-075PAUSE X-former fault-gun 1SPOT-076PAUSE Weld enable mismatch-gun 1SPOT-077PAUSE Weld in process timeout-gun 1SPOT-078PAUSE Weld complete timeout-gun 1SPOT-079WARN Got weld complete early-gun 1SPOT-080PAUSE Major alarm detected-gun 1SPOT-081WARN Minor alarm detected-gun 1SPOT-082PAUSE Bad schedule (S=…)-gun 1SPOT-083PAUSE Undefined pressure (P=*)-gun 1SPOT-084PAUSE BACKUP CLOSE timed out-gun 1SPOT-085PAUSE GUN CLOSE timed out-gun 1SPOT-086PAUSE BACKUP OPEN timed out-gun 1SPOT-087PAUSE GUN OPEN timed out-gun 1SPOT-088PAUSE Serial comm error …-gun 1SPOT-089PAUSE Serial polling timeout-gun 1SPOT-092PAUSE GUN OPEN DETECT input is on …-gun 1SPOT-093PAUSE BU CLOSE DETECT is on …-gun 1SPOT-094PAUSE BU OPEN DETECT is on …-gun 1SPOT-095PAUSE Bad pressure (P=…)-gun 1SPOT-096PAUSE Reset welder timeout-gun 1SPOT-100PAUSE Gun contactor fault …-gun 1SPOT-101PAUSE Gun open fault …-gun 1SPOT-102PAUSE Gun close fault …-gun 1SPOT-103PAUSE Backup open fault …-gun 1SPOT-104PAUSE Backup close fault …-gun 1SPOT-120PAUSE Bad Pressure (EP=…)-gun 1SPOT-121PAUSE Undefined Pressure (EP=*)-gun 1SPOT-141PAUSE Backup not closed-gun 2SPOT-143PAUSE Water saver OK fault-gun 2SPOT-144PAUSE Water flow OK fault-gun 2SPOT-145PAUSE X-former OK fault-gun 2SPOT-146PAUSE Weld enable mismatch …-gun 2SPOT-147PAUSE Weld in process timeout …-gun 2SPOT-148PAUSE Weld complete timeout…-gun 2SPOT-149WARN Got weld complete early…-gun 2SPOT-150PAUSE Major alarm detected…-gun 2SPOT-151WARN Minor alarm detected…-gun 2SPOT-152PAUSE Bad schedule (S=…)-gun 2SPOT-153PAUSE Undefined pressure (P=*)-gun 2SPOT-154PAUSE BACKUP CLOSE DETECT timed out …-gun 2SPOT-155PAUSE GUN CLOSE DETECT timed out …-gun 2SPOT-156PAUSE BACKUP OPEN DETECT timed out …-gun 2SPOT-157PAUSE GUN OPEN DETECT timed out …-gun 2SPOT-165PAUSE Bad pressure (P=…)-gun 2SPOT-166PAUSE Reset welder timeout …-gun 2SPOT-170PAUSE Gun contactor fault …-gun 2SPOT-171PAUSE Gun open fault …-gun 2SPOT-172PAUSE Gun close fault …-gun 2SPOT-173PAUSE Backup open fault …-gun 2SPOT-174PAUSE Backup close fault …-gun 2SPOT-190PAUSE Bad Pressure (EP=…)-gun 2SPOT-191PAUSE Undefined Pressure (EP=*)-gun 2SPOT-211PAUSE Backup not closed …-both gunsSPOT-212PAUSE Iso contactor fault …-both gunsSPOT-213PAUSE Water saver OK fault …-both gunsSPOT-214PAUSE Water flow OK fault …-both gunsSPOT-215PAUSE X-former OK fault …-both gunsSPOT-216PAUSE Weld enable mismatch …-both gunsSPOT-217PAUSE Weld in process timeout …-both gunsSPOT-218PAUSE Weld complete timeout …-both gunsSPOT-219WARN Got weld complete early …-both gunsSPOT-220PAUSE Major alarm detected …-both gunsSPOT-221WARN Minor alarm detected …-both gunsSPOT-222PAUSE Bad schedule (S=…)-both_gunsSPOT-223PAUSE Undefined pressure (P=*)-both gunsSPOT-224PAUSE BACKUP CLOSE DETECT timed out …-both gunsSPOT-225PAUSE GUN CLOSE DETECT timed out …-both gunsSPOT-226PAUSE BACKUP OPEN DETECT timed out …-both gunsSPOT-227PAUSE GUN OPEN DETECT timed out …-both gunsSPOT-235PAUSE Bad pressure-both gunsSPOT-236PAUSE Reset welder timeout …-both gunsSPOT-240PAUSE Gun contactor fault …-both gunsSPOT-241PAUSE Gun open fault …-both gunsSPOT-242PAUSE Gun close fault …-both gunsSPOT-243PAUSE Backup open fault …-both gunsSPOT-244PAUSE Backup close fault …-both gunsSPOT-245PAUSE Bad Pressures (EP=…)-both gunsSPOT-246PAUSE Undefined Pressures (EP=*)-both gunsSPOT-270Illegal equipment numberSPOT-271Illegal gun indexSPOT-272Illegal PX indexSPOT-273Illegal pressure profile stateSPOT-300Weld sim EnabledSPOT-301Weld enabled during spot simSPOT-302Weld sim DisabledSPOT-303SPOT-304Stroke disabled during weld retry …SPOT-306Found duplicate modelSPOT-307Gun Tip Test missing modelSPOT-308Robot Tip Test missing modelSPOT-309Tip Alignment missing modelSPOT-310Gun Tip Wear exceededSPOT-311Gun Cap Changed Length ExceededSPOT-312Gun Shank DisplacedSPOT-313Gun Tip Increase ErrorSPOT-314Robot Tip Wear exceededSPOT-315Robot Cap Changed Length ExceededSPOT-316Robot Shank DisplacedSPOT-317Robot Tip Increase ErrorSPOT-318Tip Alignment exceeds ThresholdSPOT-319Gun Tip Dress failedSPOT-320Robot Tip Dress failedSPOT-321Gun Cap Change/Type failedSPOT-322Robot Cap Change/Type failedSPOT-323Test message for RecoverySPOT-324Tip Inspection ContinueSPOT-325Tip Inspection RetrySPOT-326Tip Inspection AbortSPOT-327No Recovery Option SelectedSPOT-350WARN IWC board not foundSPOT-351WARN IWC driver not runningSPOT-352WARN Invalid IWC indexSPOT-353WARN IWC message in progressSPOT-354WARN Invalid IWC msg buffersSPOT-355WARN Invalid IWC function codeSPOT-356WARN Checksum error, IWC msg sendSPOT-357WARN Invalid buffer, IWC msg sendSPOT-358WARN Checksum error, IWC msg recvSPOT-359WARN Invalid buffer, IWC msg recvSPOT-360WARN IWC buffer too smallSPOT-361WARN Ack timeout, IWC msg sendSPOT-362WARN Timeout, IWC msg recvSPOT-363WARN IWC motherboard errorSPOT-364WARN IWC has invalid DPRAM signatureSPOT-365WARN Unsupported IWC version/rev levelSPOT-366WARN Unable to register IWC interruptSPOT-367WARN Only 40 functions allowed in a scheduleSPOT-368WARN Imp. can only come before weld FCTNSPOT-369WARN FCTN not supported by the timerSPOT-370WARN Could not download schedule …SPOT-371WARN Could not download stepper …SPOT-372WARN Could not read sequence file …SPOT-373WARN Could not download setup dataSPOT-374WARN Could not download Dynamic dataSPOT-375WARN Could not read stepper file …SPOT-376WARN Could not read setup file …SPOT-377WARN Could not read file …SPOT-378WARN IWC ID jumpers incorrectSPOT-379WARN IWC slave busySPOT-380WARN Invalid IWC Firmware VersionSPOT-381IWC(DG) system errorSPOT-382PAUSE IWC(DG) illegal stepper numberSPOT-384IWC(DG) leak inputSPOT-385PAUSE IWC(DG) illegal counter specifiedSPOT-386PAUSE Reset stepper timeout …SPOT-397Studwelding resume not allowedSPOT-399IWC FIRMWARE UPGRADEDSPOT-401PAUSE WTC E01: Controller FailureSPOT-490IWC(DG) timer now in weld …