LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm SPOT-172PAUSE Gun close fault %s-gun 2

FANUC SPOT-172 (“PAUSE Gun close fault %s-gun 2”): The Gun Close Detect input was not received within the specified timeout period. First check: Verify the input is assigned correctly; verify the input is being made when the gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$gun_cl_to).

Updated 2026-08-29 · LogrobotLM reference

Description

The Gun Close Detect input was not received within the specified timeout period.

Remedy · Remède

Verify the input is assigned correctly; verify the input is being made when the gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$gun_cl_to).

Frequently asked · Questions fréquentes

What does FANUC alarm SPOT-172 mean?
FANUC SPOT-172 (“PAUSE Gun close fault %s-gun 2”): The Gun Close Detect input was not received within the specified timeout period.
How do you troubleshoot FANUC alarm SPOT-172?
Verify the input is assigned correctly; verify the input is being made when the gun is closed; or if needed, increase the timeout value (in $spoteqsetup.$gun_cl_to).

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →