FANUC Alarm SPOT-225 — PAUSE GUN CLOSE DETECT timed out …-both guns
Manufacturer wording — PAUSE GUN CLOSE DETECT timed out %s-both guns
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC SPOT-225 (“PAUSE GUN CLOSE DETECT timed out …-both guns”): The robot timed out waiting for the gun to close. First check: Check the Equipment I/O menu, as well as all wiring.
Updated 2026-09-17 · LogrobotLM reference
Description
The robot timed out waiting for the gun to close.
Remedy
Check the Equipment I/O menu, as well as all wiring. If the input is going high, try increasing the timeout by setting $spoteqsetup[].$gun_cl_to to a bigger number. The default is 2000 ms, or 2 seconds.